WILKERSON INSTRUMENT CO., INC.

DR9051R-02 Strain Gauge (Bridge) and 4 Contact Input Multi-Point Wireless Transmitter

Wici Logo
Home Button Wilkerson Instrument Co.    800-234-1343 Shopping Cart

DR9051RUR/cUR Logo

DR9051R-02
Single Strain Gauge (Bridge)
and 4 Contact Input
Multi-Point
Wireless Transmitter

$915.00

The following information must be entered to complete your order:
See "Specifications" below for Input range limits.

Power:
Input:
Zero Scale
Full Scale
Units

 

Quantity:

 

Don't Forget Your Accessories

Enclosures Antennas Cables Accessories

 
  • Features
  • Description
  • Specifications
  • Dimensions
  • Connections
  • Direct Strain Gauge (Bridge) Input
  • 10 VDC Regulated Excitation Voltage
  • Four Digital Inputs For Contact Closure or NPN Transistor
  • Repeater Capability
  • DIN Rail Mount - Steel Clip
  • 10-30VDC Power
  • Reverse Polarity Screw-On SMA Antenna Connector
  • 915 MHz ISM Band – 2 Versions, 14 Hop Sequences
  • 2.4GHz Unlicensed Band – 1 Version, 7 Hop Sequences
  • Spread Spectrum, Frequency Hopping Technology
  • Line of Sight Range to 20 Miles With 915MHz Band Radio
  • Line of Sight Range to 10 Miles With 2.4GHz Band Radio
  • 5 Year Warranty (1 Year on Radio Module)
  • UL/cUL Recognized

The DR9051R is an RF transmitter that will accept both analog and switch contact inputs. A 12 bit A/D converter is used to digitize the analog data. Analog data and switch status is read when requested by the companion DR9050 Control Unit. The DR9050 polls the DR9051R and outputs the data in Modbus RTU format. A single DR9050 can poll up to 247 DR9051R’s utilizing a single Hop sequence.

The DR9051R has a repeater capability that is useful for data monitoring in areas where the DR9050 cannot communicate directly with a DR9051R due to distance or obstructions in the transmission path.

The switch inputs require a standard contact closure or an open collector NPN transistor.

Three radio modules are available for the DR9051R, two 915MHz band versions with 7 Hop sequences each and a 2.4GHz band version with 7 Hop sequences. They use spread spectrum, frequency hopping technology. These choices provide 21 different Hop sequences that allow 21 systems to work in the same locale without interfering with each other.

With proper antenna and cable selection and a 915MHz band version radio, the DR9051R can transmit up to 20 miles. The 2.4GHz band version can transmit up to 10 miles.

The DR9051R provides isolation between input and power source.

A 10 VDC precision power supply is built-in and provides excitation for up to four (4) 330 ohm bridges.

Screw terminal blocks that plug into the case allow easy wiring and removal of products.

All of the DR Series of products provide transient protection to help eliminate damage from lightning and from other transients created on the power and signal leads.

INPUT
Strain Gauge
Span
0.5 mV/V to 1 V/V

ACCURACY
±0.1% of Span

LINEARITY
±0.01% of Span

EXCITATION
10 VDC Precision Supply for up to 4 Strain Gauges
125 mA Maximum

SWITCH INPUT
Open Circuit Voltage Equals Power Input (10 to 30 VDC)
Closed Circuit Current 3 to 9 mA

CERTIFICATIONS
RF Module FCC Part 15.247
DR9051R UL/cUL Recognized

COMMON MODE REJECTION
100 dB, DC to 60 Hz

OPERATING TEMPERATURE
-13°F to 167°F
-25°C to 75°C

TEMPERATURE STABILITY
±(0.01% of Span)/°C Max

POWER
10 to 30 VDC 1.5 Watts Max

RADIO
Frequency
915 MHz Band 908 or 922 MHz
2.4 GHz Band 2.4000 - 2.4835 GHz

Spread Spectrum Type Frequency Hopping, Direct FM
I/O Data Rate Tx to Rx: 9600 bps

Range / Line of Sight
915 MHz Band - Up to 20 Mi.
2.4 GHz Band - Up to 10 Mi.

Receiver Sensitivity:
915 MHz Band -110 dBm @ 9600 baud
2.4 GHz Band -105 dBm @ 9600 baud

Transmitter Power:
915 MHz Band 100 mW (20 dBm)
2.4GHz Band 50 mW (17dBm)

Connector:
Reverse Polarity SMA Female

DR Wireless Series Products Dimension Drawing

TERMINAL

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

CONNECTION

Bridge Input +
Bridge Input -
Shield
Shield
Switch 1 +
Switch 1 -
Switch 2 -
Switch 2 +
Switch 3 +
Switch 3 -
Switch 4 -
Switch 4 +
10 VDC Excitation +
Excitation Common
Power +
Power -

DR4300 and DR4380A Connections Drawing
Specifications    Manual

Solutions Provider for Signal Conditioning and
Process Control Instrumentation