WILKERSON INSTRUMENT CO., INC.

SR2400 Thermocouple Input Non-Isolated
Field Rangeable Two-Wire Transmitter

Wici Logo
Home Button Wilkerson Instrument Co.    800-234-1343 Wilkerson Instrument Co Blog PageWilkerson Instrument Co LinkedIn PageShopping Cart

SR2400

SR2400
Thermocouple Input
Non-Isolated
Field Rangeable
Two-Wire Transmitter

$230.00

The following information must be entered to complete your order:
See "Specifications" below for Input range limits.

Input: Zero Scale
Full Scale
Units
  Thermocouple Type
  Open Sensor Response

Quantity:

 

Don't Forget Your Accessories
DMP2000 DIN-Rail Mounting Plate $20.00
Quantity:
Specifications
TSH-A6L NEMA-4 Aluminum Connection Head (SR, SF, TW3) $70.00
Quantity:
Specifications
XJAY Explosion Proof Housing $165.00
Quantity:
Specifications
DR1 DIN-Rail, 35mm Symmetrical, 39 inches (1 meter) $25.00
Quantity:
Specifications
 
  • Features
  • Description
  • Specifications
  • Dimensions
  • Connections
  • Provides DC Output Proportional to any Thermocouple Input**
  • Unlimited Choice of Input Ranges via Interchangeable Range Cards (Within specified range limits)
  • Reverse Polarity-Protected
  • Upscale or Downscale Burnout Protection
  • Test Points for Loop Current Monitoring without Breaking Loop Circuit
  • 50 mm Diameter Case - 33 mm Mounting Hole Spacing
  • NEMA-4 Connection Head and Explosion-Proof Housing Available
  • Low Cost
  • 5 Year Warranty

The SR2400 is alow-cost, reliable, thermocouple input two-wire transmitters for field or panel mounting in various industrial housings and enclosures. They provide a DC output current (4/20 mA) proportional to a thermocouple input. On model SR2401 the output is galvanically isolated from the input.

Ranging is accomplished via a plug-in range card which characterizes the input to the desired thermocouple types and sets the temperature range and burnout protection (upscale and downscale). Cold junction compensation is provided by a solid state temperature sensor embedded in the thermocouple input terminal strip.

The output ZERO and SPAN controls are accessible through the top of the case. Terminations are made to screw terminal connectors on top of the case.

Test points located on the transmitter’s front panel allow verification of loop current value, using a millameter, without breaking the loop current.

All Wilkerson products are designed with RFI filters and lightning protection to reduce  susceptibility to electrical noise and damage by lightning.

TYPICAL APPLICATIONS
Remote temperature data acquisition.

INPUT RANGE
select any type thermocouple (min span 5 mV)

INPUT IMPEDANCE
10 megohms

OUTPUT RANGE
4/20 mA Current limited = 35mA

MAX LOAD RESISTANCE
= [(V supply - 10)/20 mA] kilohms

RESPONSE TIME
Step Change 250 ms for 99% of final value

ACCURACY
±0.1% of span

LINEARITY
Better than ±0.05% of span (mV) (input to output)

COMMON MODE REJECTION
120 dB, DC to 60 Hz

OPERATING TEMPERATURE
-13°F to 176°F / -25°C to 80°C

TEMPERATURE STABILITY
±0.01% of span per°C

POWER
10-36 VDC, polarity-protected

SUPPLY VOLTAGE EFFECT
0.02% of span max,10-36 VDC

SR2000 Series Dimension Drawing

SR2000 Series Connections Drawing

Specifications    Manual

Solutions Provider for Signal Conditioning and
Process Control Instrumentation