WILKERSON INSTRUMENT CO., INC.

DIS971 DC Input Process Indicator
4.5 Digit Display With Optional Alarms
and Re-Transmit Output

Wici Logo
Home Button Wilkerson Instrument Co.    800-234-1343 Wilkerson Instrument Co Blog PageWilkerson Instrument Co LinkedIn PageShopping Cart

DIS971

DIS971
DC Input
Process Indicator
4.5 Digit Display
With Optional Alarms
and Re-Transmit Output

$565.00

The following information must be entered to complete your order:
See "Specifications" below for Input, Output and Display range limits.

Power:

Input:
Zero Scale
Full Scale
Units
Display: Zero Scale
Full Scale
Units (Optional)
  Display Action
Alarms: Alarm Option
Output: Output Action
(If Output Option
Selected, Enter
Output Values)
Zero Scale
Full Scale
Units

Quantity:

 

  • Features
  • Description
  • Specifications
  • Dimensions
  • Connections
  • Display Calibrated in Engineering Units (°F,°C, %, PSI, etc.) Proportional to DC Input
  • Mount, Wire and Calibrate from Front
  • Fully Isolated Output and/or 0, 1, or 2 Alarms (Optional)
  • Alarm Setpoints Adjustable without Disturbing Transmitter Output
  • Fail-Safe Alarm Operation
  • LED Alarm Status Indicator
  • Adjustable Deadband
  • 50 mV or 1 mA Minimum Input Span (10 mV available)
  • Unlimited Choice of Input / Output Ranges (Within specified range limits)
  • Wide Range Input Available
  • Fits Standard 1/8 DIN Cutout
  • Rated NEMA-4, Splashproof when Properly Installed
  • 5 Year Warranty

The DIS971 provides a display, optional isolated DC output voltage or current proportional to a DC input signal, and optional alarm setpoints. All Wilkerson products are designed with RFI filters and lightning protection to reduce susceptibility to electrical noise and damage by lightning. The digital display utilizes an auto-zero dual-slope integrating A/D converter for accuracy and stability.

All controls are accessible by removing the gasketed front access panel. The display controls are wide-ranging so that it can be calibrated to display engineering units. Decimal point selection is made with a switch, also accessible from the front.

A complete set of engineering unit labels is sent with each DIS. Once the display has been adjusted to read the correct engineering units, the alarm setpoints can be adjusted without test equipment and without disturbing the transmitter output. Either setpoint may be displayed by use of the SP CALswitch. Each setpoint has an LED to indicate alarm status. The alarms have adjustable deadbands. Terminations are made to a screw terminal connector on the rear of the case.

TYPICAL APPLICATIONS
DC process indication, control, monitoring, voltage/current scaling, isolation, buffering, noise reduction, driving, DC monitor/current limit, level/position control, HI/LO pressure alarm, power demand warning.

INPUT RANGE
Voltage
select any range between ±250 V max
(min span 50 mV)
typical inputs: 0-1 V, 0-5 V,0-10 V

Current
select any range between ±5 A max
(min span 1 mA, internal shunt)
Low Input (Option S) select any range between ±20 V max
(min span 10 mV)

INPUT IMPEDANCE
Voltage 200 kilohms

Current

Input Value Input Shunt Value
1 mA
10 mA
20 mA
4/20 mA
100 mA
1 A
5 A
100 Ohm
10 Ohm
5 Ohm
61.9 Ohm
1 Ohm
0.1 Ohm
0.01 Ohm

OPTIONS SA, DA SETPOINT
each alarm 0 to 100% of span

DEADBAND
0.25% to 100% of span

RELAY CONTACTS (spdt)
Resistive Load 5 A max, 150 W max,
240 VAC max, 30 VDC max
Inductive Load 1/8 HP max at 120/240 VAC

OPTION TX OUTPUT RANGE
Voltage select any range between ±10 V,
10 mA max load (min span 0.2 V)
Current select any range from 0 to 20 mA max,
>24 V Compliance (1200 ohms max at 20 mA)

OUTPUT RIPPLE
 (Peak-to-Peak) <0.1% of span

ISOLATION
Output/Input >500 megohms
Breakdown Voltage >600 VAC rms

RESPONSE TIME
(Range Dependent) < 100 ms
WR < 200 ms

ACCURACY
±0.1% of span

LINEARITY
Display ±0.01% of span
Output ±0.025% of span

COMMON MODE REJECTION
120 dB, DC to 60 Hz

DISPLAY
Digit Size .56" LED, 4½ digits, ±19999
Decimal Point ±1.9.9.9.9
Control Range
Zero ±19999
Span min span 100/max span 20000
Display Update 3/sec

OPERATING TEMPERATURE
14°F to 140°F /-10°C to 60°C

TEMPERATURE STABILITY
±(0.02% of span +30 μV)/°C max
Low Input (Option S)
±(0.02% of span + 1.3 μV)/°C max

POWER
115 VAC ±10%, 50 or 60 Hz (4 W max)
230 VAC ±10%, 50 or 60 Hz (4 W max)

DIN Mod Series Dimension Drawing

Terminal 1
Terminal 2
Terminal 3
Terminal 4
Terminal 5
Terminal 6
Terminal 7
Terminal 8
Terminal 9
Terminal 10
Terminal 11
Terminal 12
Terminal 13
Terminal 14
Output -
Output +
No Connection
Input +
Input -
Shield
Alarm 1 NC
Alarm 1 C
Alarm 1 NO
Alarm 2 NC
Alarm 2 C
Alarm 2 NO
Power AC L1
Power AC L2
Specifications    Manual

Solutions Provider for Signal Conditioning and
Process Control Instrumentation