Specialized Fan & Pump Control
Variable Frequency
Drive
FEATURES
 |
Variable torque rating for HVAC &
pump |
 |
Sensorless and space vector control |
 |
150% torque in overall range |
 |
Motor parameter auto-tuning |
 |
High speed 32 bits digital signal
processor |
 |
0.7~15Hz carrier frequency |
 |
Build in multi-motor control (up to 4) |
 |
Built-in process PID control |
 |
Up/down & 3-wire operational function |
 |
Built-in ModBus (RP485) communication |
 |
0~10VDC, -10~+10VDC analog input |
 |
PNP/NPN selectable signal input |
 |
External NTC input |
 |
Optional braking unit |
 |
Cooling fan On/Off control |
 |
Optional extendable sub-boards, (ProfiBus
& DeviceNet) |
APPLICATIONS
 |
HVAC systems |
 |
Building automation systems |
 |
Centrifugal fans and pumps |
 |
Water and waste treatment |
 |
Blowers |
 |
Chillers |
SPECIFICATIONS
230V Class (7.5 ~ 40HP)
|
Model Number
(CI-xxx-P2)
|
007 |
010 |
015 |
020 |
025 |
030 |
040 |
|
Motor
Rating
|
HP |
7.5 |
10 |
15 |
20 |
25 |
30 |
40 |
|
kW |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
|
Output
Ratings
|
Capacity [kVA] |
9.1 |
12.2 |
17.5 |
22.9 |
28.2 |
33.5 |
46 |
|
FLA [A] |
24 |
32 |
46 |
60 |
74 |
88 |
122 |
|
Voltage |
3 Phase, 200 ~ 230 V |
|
Frequency |
0 ~ 400 Hz |
|
Input
Ratings
|
Voltage |
3 Phase, 200 ~ 230 V (± 10 %) |
|
Frequency |
50 ~ 60 Hz (± 5 %) |
|
Weight [lbs] |
16.5 |
17.0 |
30.4 |
31.5 |
42.8 |
44.1 |
48 |
460V Class (7.5 ~ 40HP)
|
Model Number
(CI-xxx-P4)
|
007 |
010 |
015 |
020 |
025 |
030 |
040 |
|
Motor
Rating1 |
HP |
7.5 |
10 |
15 |
20 |
25 |
30 |
40 |
|
kW |
5.5 |
7.5 |
11 |
15 |
18.5 |
22 |
30 |
|
Output Ratings |
Capacity2 [kVA] |
9.1 |
12.2 |
18.3 |
22.9 |
29.7 |
34.3 |
45 |
|
FLA [A] |
12 |
16 |
24 |
30 |
39 |
45 |
61 |
|
Frequency |
0 ~ 400 Hz |
|
Voltage |
380 ~ 460 V 3 |
|
Input Ratings |
Voltage |
3 Phase, 380 ~ 460 V (±
10 %) |
|
Frequency |
50 ~ 60 Hz (±
5 %) |
|
Weight [lbs] |
17.0 |
17.0 |
30.6 |
31.7 |
44.1 |
44.1 |
48 |
Indicates the maximum
applicable capacity when using 4 pole motor.
Rated capacity (√
3*V*I)is based on 220V for 200V class and 440V for 400V class.
Maximum output voltage will
not be greater than the input voltage. Output voltage less than the input
voltage can be programmed.
Common:
|
CONTROL |
Control Method |
V/F Control, (Sensorless Vector PWM) |
|
Frequency Setting Resolution |
Digital Reference: 0.01 Hz (Below 99 Hz), 0.1 Hz (100
Hz & over)
Analog Reference: 0.06 Hz / 60 Hz
|
|
Frequency Accuracy |
Digital: 0.01 % of Max. Output Frequency
Analog: 0.1 % of Max. Output Frequency
|
|
V/F Ratio |
Linear, Squared Pattern, User V/F |
|
Overload Capacity |
|
|
Torque Boost |
Manual Torque Boost (0 ~ 15 %), Auto Torque Boost |
|
OPERATION |
Input Signal |
Operator Control |
32 character LCD
keypad • Terminals • Modbus RTU Communication, RP485, ProfiBus-DP,
DeviceNet, F-Net |
|
Frequency Setting |
Analog: 0 ~ 10V / 4 ~ 20mA / Additional port for Sub-Board (0 ~ 10V)
Digital: Keypad, Communication: ModBus
|
|
Start Signal |
Forward, Reverse |
|
Multi-Step |
Up to 8 Speeds can be Set (Use Multi-Function Terminal) |
|
Multi Step Accel/Decel Time |
0 ~ 6000 seconds. Maximum 8 pre-defined steps using
multi-function terminals
|
|
Emergency Stop |
Interrupts the Output of Inverter |
|
Jog |
Jog Operation |
|
Auto Operation |
Operates from Internal Sequence by Setting Multi-Function Terminal (5 Way * 8 Step) |
|
Fault Reset |
Trip Status is Removed when Protection Function is Active |
|
Output Signal |
Operating Status |
Frequency Detection Level, Overload Alarm, Stalling, Over Voltage, Under Voltage, Inverter Overheating, Running, Stop, Constant Speed,
Fault output (Relay and Open collector) Inverter By-Pass, Speed Searching, Auto-Operation Step, Auto-Operation Sequence |
|
Fault Output |
Contact Output (30A, 30C, 30B) – AC250V 1A, DC30V 1A |
|
Indicator |
Choose 1 from Output Frequency, Output Current, Output Voltage, DC Voltage
Output Torque (Output Voltage: 0 ~ 10V)
|
|
Protective Function |
Inverter Trip |
Over Voltage, Under Voltage, Over Current, Fuse Open, Ground Fault, Inverter Overheating, Motor Overheating, Output Phase Open,
Overload Protection, External Fault 1, 2, Communication Error, Loss of Speed Command, Hardware Fault, Option Fault etc.
|
| |
Inverter Alarm |
Stall Prevention, Overload Alarm, Temperature Sensor Fault |
|
Display |
Keypad |
Operation Information |
Output Frequency, Output Current, Output Voltage, Frequency Value Setting, Operating Speed, DC Voltage |
|
Trip Information |
Indicates a Fault when the Protection Function activates, Retains Up to 5 Faults |
|
Environment |
Ambient Temperature |
-10 °C ~ 40
°C (14 °F ~ 104
°F) |
|
Storage Temperature |
-20 °C ~ 65
°C (-4 °F ~ 149
°F) |
|
Ambient Humidity |
90 % RH Max.(Non-Condensing) |
|
Altitude - Vibration |
Below 1,000m or 3,300ft · Below 5.9m/sec˛(=0.6g) |
|
Application Site |
No Corrosive Gas, Combustible Gas, Oil Mist, or Dust |
|
Cooling Method |
Forced Air Cooling |
ORDERING INFORMATION
| 230V |
|
Model |
Motor
Rating |
|
HP |
kW |
| CI-007-P2 |
7.5 |
5.5 |
| CI-010-P2 |
10 |
7.5 |
| CI-015-P2 |
15 |
11 |
| CI-020-P2 |
20 |
15 |
| CI-025-P2 |
25 |
18.5 |
| CI-030-P2 |
30 |
22 |
| CI-040-P2 |
40 |
30 |
| 460V |
|
Model |
Motor
Rating |
|
HP |
kW |
| CI-007-P4 |
7.5 |
5.5 |
| CI-010-P4 |
10 |
7.5 |
| CI-015-P4 |
15 |
11 |
| CI-020-P4 |
20 |
15 |
| CI-025-P4 |
25 |
18.5 |
| CI-030-P4 |
30 |
22 |
| CI-040-P4 |
40 |
30 |
|