GS Series
Variable Frequency
Drive
FEATURES
Intelligent High Performance
 |
Precise
control and high starting torque (up to 150% at 0.5 Hz (Space Vector PWM by
IGBT)
|
 |
Auto
carrier frequency adjusts inversely in relation to temperature of drive for
long term reliability
|
 |
Ground
fault protection of output terminal during run
|
 |
Quiet
operation thanks to fan control coordination with motor start/stop
|
Easy to set up and operate
 |
New
4-direction keypad makes parameter settings a snap
|
 |
Trip-free
operation algorithm
|
 |
Auto
& manual torque boost
|
 |
Optimum
acceleration and deceleration curves set automatically for maximum torque -
or choose 8 preset speeds
|
Flexible
 |
ModBus
485 communication for easy integration
|
 |
Built
in dynamic braking (provision for external braking) provides up to 150%
braking torque
|
 |
Removable,
downloadable keypad for easy programming
|
 |
PNP/NPN
selectable signal
|
 |
Built-in
fault memory (stores last five fault conditions)
|
 | CE UL cUL ISO9001 |
DESCRIPTION
Built-in PID Control for easy direct
integration.
Built-in PID controls temperature, pressure, etc. through the proportional,
integral and differential calculus between thye feedback value and reference
value in closed loop.
Built-in Communication Interface
The GS series integrates popular communication interfaces such as Modbus-RTU,
and RS232/485.
Optimum Acceleration and Deceleration
Trip-free mode achieves maximum torque during accel/deceleration. The
32-bit DSP CPU monitors the current transition to program an optimum curve below
trip-triggering levels.
SPECIFICATIONS
230V Class (0.5 ~ 5.4HP)
|
Model Number
(CI-xxx-G2) |
000 |
001 |
002 |
003 |
005 |
|
Motor
Rating
|
HP |
0.5 |
1 |
2 |
3 |
5 |
|
kW |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
|
Output
Ratings
|
Capacity [kVA] |
0.95 |
1.9 |
3.0 |
4.5 |
6.1 |
|
FLA [A] |
2.5 |
5 |
8 |
12 |
16 |
|
Frequency |
0 ~ 400 Hz |
|
Voltage |
200 ~ 230 V |
|
Input
Ratings
|
Voltage |
3 Phase
200 ~ 230 V (+ 10 %, -15%)
|
|
Frequency |
50 ~ 60 Hz (± 5 %) |
|
Weight [lbs] |
1.7 |
1.7 |
2.47 |
4.06 |
4.17 |
460V Class (0.5 ~ 5.4HP)
|
Model Number
(CI-xxx-G4) |
000 |
001 |
002 |
003 |
005 |
|
Motor
Rating1
|
HP |
0.5 |
1 |
2 |
3 |
5 |
|
kW |
0.4 |
0.75 |
1.5 |
2.2 |
3.7 |
|
Output
Ratings
|
Capacity2 [kVA] |
.95 |
1.9 |
3.0 |
4.5 |
6.1 |
|
FLA [A] |
1.25 |
2.5 |
4 |
6 |
8 |
|
Frequency |
0 ~ 400 Hz |
|
Voltage |
380 ~ 460 V3 |
|
Input
Ratings
|
Voltage |
3 Phase, 380 ~ 460 V (+ 10 %, -15%) |
|
Frequency |
50 ~ 60 Hz (± 5 %) |
|
Weight [lbs] |
1.7 |
1.7 |
2.47 |
4.06 |
4.17
|
Common:
|
CONTROL |
Control method |
Sensorless Vector, V/F control (Space
Vector PWM) |
|
Frequency setting resolution |
Digital reference : 0.01 Hz (below 99 Hz), 0.1 Hz
(100 Hz and over)
Analog reference : 0.03 Hz at 50 Hz
|
|
Frequency accuracy |
Digital: 0.01 % of max. output frequency
Analog: 0.1 % of max. output frequency
|
|
V/F ratio |
Linear, Square, User V/F |
| Overload capacity |
150 % of rated
current for 1 min., 30 seconds at 200% (characteristic is inversely
proportional to time) |
| Torque boost |
Manual torque boost (0 ~ 15 %), Auto torque boost |
|
Multi-function input terminals |
Total 3 inputs (programmable) |
| Analog
Output |
0 ~ 10V linear |
|
|
|
OPERATION |
Input Signal |
Operator
control |
4 digit LED
keypad / terminal / ModBus communications |
|
Frequency setting |
Analog : 0 ~ 10V / 4 ~ 20 mA, Digital: keypad,
Communication: ModBus |
|
Start signal |
forward, reverse |
Multi-step
operation |
Up to 8 speeds (use multi-function terminal) |
|
Multi Step accel/decel time |
0 ~ 6,000 sec,
maximum 8 pre-defined steps using multi-function terminals |
|
Emergency stop |
Interrupts the output of the inverter |
|
Jog |
Jog operation |
|
Fault reset |
Reset faults when protective function is active |
|
Output Signal |
Operating status |
Frequency detection, Overload alarm,
stall, overvoltage, undervoltage, inverter overheat, run, stop, constant speed, speed
searching, fault output (relay and open collector output) |
|
Indicator |
Choose 1 from Output frequency, output current, output voltage, DC
voltage
(Output pulse: 500Hz, Output voltage: 0 ~ 10V)
|
| |
|
Protection |
Inverter trip |
Overvoltage, undervoltage, overcurrent, inverter overheating, motor
over heating, input/output phase loss, input/output miss-wiring, overload
protection, communication error, loss of speed command, hardware fault |
|
Inverter alarm |
Stall prevention, overload alarm |
| |
|
Environment |
Ambient temperature |
-10° ~ 50° C |
|
Storage temperature |
-20° ~ 65° C |
|
Ambient humidity |
90 % RH max.(Non condensing) |
|
Altitude.Vibration |
Below 1,000 m · below 5.9m/sec˛(=0.6g) |
|
Application site |
No corrosive gas, combustible gas, oil mist, or dust |
ORDERING INFORMATION
| 230V |
|
Model |
Motor
Rating |
|
HP |
kW |
| CI-000-GS2 |
0.5 |
0.4 |
| CI-001-GS2 |
1 |
0.75 |
| CI-002-GS2 |
2 |
1.5 |
| CI-003-GS2 |
3 |
2.2 |
| CI-005-GS2 |
5 |
3.7 |
| 460V |
|
Model |
Motor
Rating |
|
HP |
kW |
| CI-000-GS4 |
0.5 |
0.4 |
| CI-001-GS4 |
1 |
0.75 |
| CI-002-GS4 |
2 |
1.5 |
| CI-003-GS4 |
3 |
2.2 |
| CI-005-GS4 |
5 |
3.7 |
|