Model 88 F
Flushmount
Pressure Transmitter
FEATURES
 |
A high-quality, full
featured transmitter at just 1.6 lbs. (720 grams) |
 |
Designed to mount flush
against process media |
 |
All welded 316 stainless
steel construction (no aluminum) |
 |
Standard Hastelloy C
diaphragm |
 |
Ranges from 0-3 to 0-300
psig (0-.2 to 0-20 bar) |
 |
±0.25% accuracy |
 |
Zero and span adjustability |
 |
Full 5:1 turndown |
 |
4-20 mA output at 12-40 VDC |
 |
FM & CSA explosion
proof and intrinsically safe |
 |
CENELEC-Approved version
available |
 |
316 stainless steel
coupling and plug available for mounting and maintenance. |
DESCRIPTION
The Model 88F is a durable,
full featured, flush diaphragm pressure transmitter. It is designed to mount
flush against process media and to prevent any media particles, such as from
paper slurry, from collecting at the diaphragm. Its rugged 316 stainless steel
and Hastelloy C construction make it perfect for tough environments and
corrosive media conditions.
The compact size and weight of
the Model 88F transmitter eliminate any complicated mounting hardware and
mechanical supports.
The integral junction box
permits simple field wiring, too. All of this reduces your installation time
substantially. And with the cover retained by a stainless steel chain and no
internal jumpers for span turndown, losses due to misplaced or dropped parts are
eliminated.
A 4-20 mA output is standard
with a 12-40 VDC power supply. Approvals include FM and CSA for both
intrinsic safety and explosion proof ratings: CENELEC approval for intrinsic
safety is also available. The Model 88F also meets NACE standards.
SPECIFICATIONS
| Functional Specifications: |
Pressure Specifications: |
|
Service:
Liquid, Gas or Vapor
Range Limits:
0/3 to 0/15 psi (0/.2 to 0/1 bar)
0/6 to 0/30 psi (0/.4 to 0/2 bar)
0/20 to 0/100 psi (0/1.4 to 0/7 bar)
0/60 to 0/300 psi (0/4 to 0/20 bar)
Output:
4-20 mADC, limited to 30 mADC
Power Supply:
12 to 40 VDC with reverse polarity protection
Loop Resistance:
1400 ohms max @ 40 volts
Turndown:
5:1
Zero Adjust:
±10%
Span Adjust:
±10%
Temperature Limits:
Electronics (Ambient) -40F to 140F
(-40C to 60C)
Process Interface -40F to 212F (-40C to 100C)
Storage -40 to 212F (-40C to 100C)
Overrange:
300% upper range limit
Humidity Limits:
0-100% RH
|
Accuracy:
±0.25% of calibrated span including linearity, hysteresis and repeatability.
Response Time:
Time constant of 20 milliseconds.
Stability:
±0.5% of upper range limit for six months
Temperature Effect: (includes
zero and span)
Compensated -20 to 180F (-29 to 82C)
Between 30F and 130F (-1C and 54C): +1% of URL per 50F (28C)
Between -20F and 180F (-29C and 82C): +1.6% of URL per 50F (28C)
Power Supply Effect:
±0.005% F.S. per volt
Surge Protection:
Standard
Vibration Effect:
±0.1% of upper range limit for 3 g to 200 Hz
Position Effect:
.05% /90 Deg Tilt
Overrange Effect:
±0.15% F.S. per 300% of max. range
|
| Physical Specifications: |
|
|
Materials of Construction
Process Wetted Parts:
316 SS
Diaphragm:
Hastelloy C
Non Wetted Parts:
316 SS
Cast Head:
CF-8M (316 Cast SS)
|
"O" Ring:
Buna N
Fill Fluid:
DC 200 Silicone (Standard)
Electrical Connection:
1/2 NPT Female
Weight:
1.67 lbs. (720 grams)
|
| Classifications: |
|
|
Factory Mutual:
Intrinsically safe for Class I, II,
III, Division 1, Groups A, B, C, D, E, F, G for hazardous locations per AMETEK
Dwg. BK750407.
Entity Requirement: Imax = 225mA, Vmax = 36B, CI = 0.126uf, LI = 0mH.
Explosion Proof for Class I, II, III, Division 1, Groups B, C, D, E, G for
hazardous locations.
NEMA 4 Enclosure.
Canadian Standards
Association:
Exia-Intrinsically safe for Class
I, Division 1 & 2, Groups A, B, C, D; Class II, Groups E, F, G when
connected per AMETEK Dwg. BK750483.
Explosion Proof for Class I, Division 1, Groups B, C, D; Class II, Groups E, F,
G; Class III for Hazardous locations. Enclosure 4, Temperature Code T3C (160 C)
CENELEC,
Intrinsically Safe: EExiallCT3 |
ORDERING INFORMATION
|
Model |
88F |
| Pressure
Range |
002 =
0/3 to 0/15 psi (0/.2) to 0/1 bar)
003 = 0/6 to 0/30 psi (0./4 to 0/2 bar)
004 = 0/20 to 0/100 psi (0/1.4 to 0/7 bar)
005 = 0/60 to 0/300 psi (0/4 to 0/20 bar) |
| Material |
Base Diaphragm
Fill
A = 316SS Hastelloy
C Silicone Oil |
| Output |
2 = 4 -
20 mADC |
| Approval |
FM
& CS = Either code acceptable. Approved by Factory Mutual &
Canadian Standard Assoc. for I.S. and Exp. Proof
CL = Approved by CENELEC to I.S. only |
| Coupling |
SC =
316 SS Coupling; Teflon Gasket
PC = 316 SS Plug and Coupling; Teflon Gasket
NC = No Coupling; Teflon Gasket |
| Calibration
Range |
(specify)
Will be calibrated at maximum range in psi if not specified. |
Example:
88F-004-A-2-CS-(0 to 75 psi)
Model 88F Pressure Transmitter, 100 psi max. range, 316 SS base, Hastelloy C
diaphragm, silicone oil fill, output at 4-20 mADC, CSA and FM approved, 316 SS
plug and coupling and calibrated so 0 to 75 psi pressure gives 4 to 20 mADC
output.
|